1926.353Ventilation & Protection
Mechanical Ventilation
- Local exhaust ventilation shall consist of freely movable hoods intended to be placed by the welder or burner as close as practicable to the work
- This system shall be of sufficient capacity and so arranged as to remove fumes and smoke at the source and keep the concentration of them in the breathing zone within safe limits